SampleTek Home Contact SampleTek Links to resources and review for our products News about SampleTek

SampleTek Logo, Innovator of Sample Preparation Equipment
Shows movement of Extractor

Model 24VE Programmable
Vacuum Extractor

Repeatable Results

The Model 24VE Programmable Vacuum Extractor provides a means to pass a precise amount of extractant through multiple samples in a precise amount of time. This is accomplished by drawing the extractant into the receiving syringes by mechanical means controlled by a programmable micro-processor.

This technique of extraction by leaching provides a means to obtain repeatable verifiable results as for Extractable Acidity and Cation Exchange Capacity (CEC). Extractants such as 1N NH4OAc, 1N KCL, and Acid Oxalate can be used to extract ions for analyses by various instrumentation techniques. Water extractable ions can be extracted from saturated pastes using the 9cm paste extraction cup accessory.

Extractions are accomplished by passing a selected amount of extractant through samples in a precise amount of time regardless of the density or porosity of the sample.

This occurs as the upper two discs of the extractor move upward resulting in volume change in the extraction syringe retained by the fixed lower disc. The Model 24VE handles up to 24 samples at a time and can be set to complete the extractions in a time period ranging from 5 minutes to 24 hours with extractant volumes of 10 to 60 milliliters.

Download Brochure as PDF or ZIP.
Download Operator's Manual as PDF or ZIP


Extractor Control PanelVacuum Extractor control panel is equipped with an on/off switch, 16 key set-up pad and a red 'in operation' indicator.


All operations are set up by use of a sixteen button keypad located on the front panel. An eighty character display is used by the operator for reliable set-ups.

The Model 24VE is equipped with a removable electrical cord allowing the unit to be rotated for easy loading.


24 sample positions are numbered
The 24 sample positions are numbered for reference purposes.


Click image below to open new browser window with enlarged view. Close new window to return here.

Illustration of Extractor

FIGURE 1

Shows the proper configuration used when extracting samples for procedures such as Cation Exchange Capacity (CEC) determinations. The middle cylinder (#9256) containing the sample can be equipped with an auxiliary reservoir for the extractant by using an upper cylinder reservoir with stopper (#9156). This may be advantageous for some procedures in that it supplies continuous fresh extractant dripping through to the sample below in the sample cylinder. This is accomplished due to the sealed configuration between the cylinders thus allowing the extractant to drip onto the sample at the same rate that it passes through the sample. Vacuum is created in the lower extraction syringe (#9456) as it is withdrawn by the extraction apparatus.

Extractor at work

As illustrated above in Figures 1, 2 and 3.



Download Brochure as PDF or ZIP.
Download Operator's Manual as PDF or ZIP.

Paste Extraction CupFIGURE 2

Shows the proper configuration using the paste extraction cup (#9606). This configuration provides a means for paste extraction or filtration. Two filters papers are used: 4.25 cm (#9656) over the center hole and a 9 cm filter (#9706) over that.

FIGURE 3

Shows the proper configuration using a disposable syringe filter or syringe filter holder for replaceable filters. In this configuration a syringe spacer ring (#9206) is used to retain the sample cylinder in position. By varying filtration porosity and apparatus withdrawal rate a variety of sample types can be processed, whether in or out of solution or of high or low viscosity.